Drum Cooler
We offer you a complete food drying solution with long-term technical support and fast response. Customization is available. Superior quality and Best price!
Ultra-Low Temperature Refrigerators series
Industrial ultra-low temperature freezers and low-temperature refrigerators can be custom-made according to user requirements to provide ultra-low temperature solutions. They excel in ultra-low temperature preservation, freezing, and refrigeration, boasting strong load-bearing capacity. They are suitable for simulating working conditions, low-temperature assembly processing, and material treatment.
1. Introduction to Industrial Ultra-Low Temperature Refrigerators:
Industrial low-temperature refrigerators, also known as industrial ultra-low temperature storage cabinets or freezers, are essential equipment in biochemical and molecular biology laboratories. They are primarily used for large-scale industrial low-temperature testing and the preservation of biological samples, pharmaceuticals, and fresh items like fruits, vegetables, and meats.
2. Industrial Ultra-Low Temperature Refrigerator Features:
2.1 Microcomputer control, foldable temperature controller, digital temperature display, adjustable in increments of 0.1 degrees, adjustable temperature range within the cabinet from -20 degrees to -125 degrees.
2.2 Multiple safety protections for reliable operation.
2.3 Super-large capacity and load-bearing design.
2.4 Optional compressors from France Tecumseh, Germany Bitzer, or Bitzer with dual-stage supercooling refrigeration technology.
2.5 Equipped with self-diagnostic function, refrigeration overload protection, high-pressure switch, overload relay, thermal protection device, and various safety functions to ensure safe usage.
2.6 Three-layer sealing, molded insulation layer, extra-thick polyurethane foam insulation layer for better insulation; embedded vacuum insulation board.
2.7 User-friendly design for flexibility and convenience.
2.8 Suitable for use in mechanical production workshop environments.
2.9 Large condensation design to ensure cooling efficiency in the workshop environment.
2.10 Designed for high capacity, with strong load-bearing capacity.
2.11 Adjustable compressor start and stop temperature difference.
2.12 Various fault alarms (over-temperature alarm, sensor alarm, high-pressure alarm, compressor overheat alarm).
2.13 Start-up delay protection.
2.14 All components are securely grounded.
2.15 LED display for clear indication of internal and set temperatures; configurable over-temperature alarm and internal temperature, with fault indication function.
2.16 Customizable non-standard sizes and ultra-low-temperature freezing rooms (capable of producing ultra-low-temperature freezing rooms within 100 cubic feet at -100 degrees).
2.17 Optional features such as a color touch screen and temperature recorder.
2.18 Customizable for various models, temperatures, and capacities of ultra-low temperature refrigerators.
3. List of Industrial Ultra-Low Temperature Refrige
Industrial ultra-low temperature freezers and low-temperature refrigerators can be custom-made according to user requirements to provide ultra-low temperature solutions. They excel in ultra-low temperature preservation, freezing, and refrigeration, boasting strong load-bearing capacity. They are suitable for simulating working conditions, low-temperature assembly processing, and material treatment.
Parameters/Model | TF-B80-250WA | TF-B80-500WA | TF-B80-1000WA | TF-B80-2000WA | TF-B80-4000WA |
Volume | 250L | 500L | 1000L | 2000L | 4000L |
Temperature Range | Room Temperature ~ -80℃ | Room Temperature ~ -80℃ | Room Temperature ~ -80℃ | Room Temperature ~ -80℃ | Room Temperature ~ -80℃ |
Load Capacity | 300KG | 800KG | 1000KG | 2000KG | 4000KG |
Cooling Capacity | 500W | 1500W | 2000W | 5000W | 12000W |
Temperature Uniformity | Constant Speed | Constant Speed | Constant Speed | Constant Speed | Constant Speed |
Cooling Method | Air-cooled | Air-cooled | Air-cooled | Water-cooled | Water-cooled |
Internal Dimensions(mm) | 650×450×650 | 1200×850×1000 | 1500×850×1000 | 2000×900×1200 | 2500×1200×1200 |
External Dimensions(mm) | 850×650×800 | 1350×1150×1300 | 1800×1150×1300 | 2300×1200×1400 | 2800×1500×1400 |
Power(kW) | 1.5 | 3 | 4.5 | 16.5 | 26.6 |
Material | Polyurethane with Stainless Steel | ||||
Door Opening Mechanism | Top-Opening | ||||
Temperature Control Method | Microcomputer Fully Automatic | ||||
Insulation Method | Static | ||||
Sensor | PT100 Platinum Resistance Thermometer(PRT),±100℃ | ||||
Indicator Light | Power Failure Indicator Light,Compressor Running Indicator Light,Compressor Fault Indicator Light and Fan Fault Indicator Light | ||||
Safety Protection | Protection:Leakage circuit Breaker,High and Low Voltage, Over/Under Voltage, Phase Loss,Overcurrent,Dual Door Seals |
Parameters/Model | TF-B120-250WA | TF-B120-500WA | TF-B120-1000WA | TF-B120-2000WA | TF-B120-4000WA |
Volume | 250L | 500L | 1000L | 2000L | 4000L |
Temperature Range | Room Temperature ~ -120℃ | Room Temperature ~ -120℃ | Room Temperature ~ -120℃ | Room Temperature ~ -120℃ | Room Temperature ~ -120℃ |
Load Capacity | 300KG | 800KG | 1000KG | 2000KG | 4000KG |
Cooling Capacity | 5500W | 15000W | 26000W | 55000W | 120000W |
Temperature Uniformity | Constant Speed | Constant Speed | Constant Speed | Constant Speed | Constant Speed |
Cooling Method | Water-cooled | Water-cooled | Water-cooled | Water-cooled | Water-cooled |
Internal Dimensions(mm) | 650×450×650 | 1200×850×1000 | 1500×850×1000 | 2000×900×1200 | 2500×1200×1200 |
External Dimensions(mm) | 850×650×850 | 1600×1250×1300 | 1900×1250×1400 | 2400×1300×1500 | 2900×1600×1500 |
Power(kW) | 2.75 | 7.5 | 11.2.5 | 15 | 30 |
Material | Polyurethane with Stainless Steel | ||||
Door Opening Mechanism | Manually Top-Opening | ||||
Temperature Control Method | Microcomputer Fully Automatic | ||||
Insulation Method | Static | ||||
Sensor | PT100 Platinum Resistance Thermometer(PRT),±100℃ | ||||
Indicator Light | Power Failure Indicator Light,Compressor Running Indicator Light,Compressor Fault Indicator Light and Fan Fault Indicator Light | ||||
Safety Protection | Protection:Leakage circuit Breaker,High and Low Voltage, Over/Under Voltage, Phase Loss,Overcurrent,Dual Door Seals |
Parameters/Model | TF-B150-250WA | TF-B150-500WA | TF-B150-1000WA | TF-B150-2000WA | TF-B150-4000WA |
Volume | 250L | 500L | 1000L | 2000L | 4000L |
Temperature Range | Room Temperature ~ -150℃ | Room Temperature ~ -150℃ | Room Temperature ~ -150℃ | Room Temperature ~ -150℃ | Room Temperature ~ -150℃ |
Load Capacity | 300KG | 800KG | 1000KG | 2000KG | 4000KG |
Cooling Capacity | 6500W | 18000W | 37000W | ||
Temperature Uniformity | Constant Speed | Constant Speed | Constant Speed | ||
Cooling Method | Water-cooled | Water-cooled | Water-cooled | ||
Internal Dimensions(mm) | 650×450×650 | 1200×850×1000 | 1500×850×1000 | 2000×900×1200 | 2500×1200×1200 |
External Dimensions(mm) | 850×650×850 | 1600×1250×1300 | 1900×1250×1400 | 2400×1300×1500 | 2900×1600×1500 |
Power(kW) | 3 | 9 | 12 | 25 | 55 |
Material | Polyurethane with Stainless Steel | ||||
Door Opening Mechanism | Hydraulic Manual | ||||
Temperature Control Method | Microcomputer Fully Automatic | ||||
Insulation Method | Static | ||||
Sensor | PT100 Platinum Resistance Thermometer(PRT),±100℃ | ||||
Indicator Light | Power Failure Indicator Light,Compressor Running Indicator Light,Compressor Fault Indicator Light and Fan Fault Indicator Light | ||||
Safety Protection | Protection:Leakage circuit Breaker,High and Low Voltage, Over/Under Voltage, Phase Loss,Overcurrent,Dual Door Seals |